27Part 2: DSP-402 Implementation
Power Disabled
Power Enabled
Fault
Start
Not Ready to Switch On
Fault Reaction Active
Fault
Switch On Disabled
Ready To Switch On
0
1
2
7
4
5
6
Switched On
Operation Enable Quick Stop Active
9 38
16
11
10 12
14
13
15
Controlword 6040h
Internal
Event
Statusword
6041h
SUPPORT FOR FAULT
STATES UNDER
DEVELOPMENT
Figure 4.2: State Machine States/Transitions Block Diagram
Notes On State Transitions
Commands directing a change in state are processed completely and the new state achieved before additional state
change commands are processed.
Transitions 0 and 1 occur automatically at drive power-on or reset. All other state changes must be directed by the
host.
Drive function disabled indicates that no current is being supplied to the motor.
Drive function enabled indicates that current is available for the motor and profile position and profile velocity
reference values may be processed.