Intelligent-motion-systems MDrive DSP-402 Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware Intelligent-motion-systems MDrive DSP-402. Intelligent Motion Systems MDrive DSP-402 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 64
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Excellence in Motion
DSP-402
APPLICATION GUIDE
TM
TM
CAN
open
TM
FORCE
DRIVE
CAN
open
Vista de pagina 0
1 2 3 4 5 6 ... 63 64

Indice de contenidos

Pagina 1 - APPLICATION GUIDE

Excellence in MotionDSP-402 APPLICATION GUIDETMTMCANopenTMFORCEDRIVECANopen

Pagina 2 - Revision R020507

2 MDrivePlus CANopen R020507Page Intentionally Left Blank

Pagina 3 - Contents

3Part 2: DSP-402 ImplementationSection 1Introduction to the MDrivePlus CANopen DSP-402 ImplementationIntroductionThis document describes the Operatio

Pagina 4

4 MDrivePlus CANopen R020507Device ControlThe starting and stopping of the drive and several mode specific commands are executed by the state machine.

Pagina 5

5Part 2: DSP-402 ImplementationTrajectory GeneratorThe chosen operation mode and the corresponding parameters (objects) define the input of the Trajec

Pagina 6

6 MDrivePlus CANopen R020507Object FormattingThis manual will display the Object and Entry data using the model detailed below.Object DescriptionIndex

Pagina 7 - List of Tables

7Part 2: DSP-402 ImplementationPDO MappingDescribes whether (Yes) or not (No) the Index may be mapped to a PDO (Process Data Object). If yes it may be

Pagina 8

8 MDrivePlus CANopen R020507Page Intentionally Left Blank

Pagina 9 - Application guide

9Part 2: DSP-402 ImplementationSection 2Accessing The MDrivePlus CANopenIntroductionThe access from the CAN network to the drive is done through data

Pagina 10 - Page Intentionally Left Blank

10 MDrivePlus CANopen R020507PDO MappingThe MDrivePlus CANopen allows you to map objects to PDOs to reduce the transfer application data more efficien

Pagina 11 - Section 1

11Part 2: DSP-402 ImplementationPDO ObjectsConsumer PDO1 (RPDO1) 1400h (Object Description) Index Name Object Code Data Type Category1400hReceive PDO

Pagina 12 - Modes of Operation

The information in this book has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies.Intelli

Pagina 13

12 MDrivePlus CANopen R020507Consumer PDO2 (RPDO2) 1401h (Object Description) Index Name Object Code Data Type Category1401hReceive PDO2 Parameter Rec

Pagina 14

13Part 2: DSP-402 ImplementationConsumer PDO3 (RPDO3) 1402h (Object Description) Index Name Object Code Data Type Category1402hReceive PDO3 Parameter

Pagina 15 - Category

14 MDrivePlus CANopen R020507Producer PDO1 (TPDO1) 1800h (Entry Description) Sub-Index Description Category Access Value Range Default00h Highest Supp

Pagina 16 - 8 MDrivePlus CANopen R020507

15Part 2: DSP-402 Implementation1A01h (Object Description – Mapping Parameters)Index Name Object Code Data Type Category1A01hTransmit PDO2 Mapping Rec

Pagina 17 - Section 2

16 MDrivePlus CANopen R0205071A02h (Entry Description – Mapping Parameters)Sub-Index Description Category Access Value Range Default00h Highest Suppor

Pagina 18

17Part 2: DSP-402 ImplementationSection 3Manufacturer Specific ObjectsIntroductionThe objects detailed in this section are IMS manufacturer specific co

Pagina 19 - PDO Objects

18 MDrivePlus CANopen R020507Object 2002h: I/O Discretes (Config)Object DescriptionIndex2002hNameConfig Input SwitchesObject CodeVARData TypeUnsigned

Pagina 20

19Part 2: DSP-402 ImplementationObject DescriptionIndex2004hNameInput Filter MaskObject CodeVARData TypeUnsigned 8Entry DescriptionSub-Index Descripti

Pagina 21

20 MDrivePlus CANopen R020507Object 2010h: Analog InputObject DescriptionIndex2010hNameAnalog InputObject CodeVARData TypeSee Entry Desc.Entry Descrip

Pagina 22

21Part 2: DSP-402 ImplementationObject 2031h: Unit Options (Encoder Enable, Capture In/Trip Out)Object DescriptionIndex2031hNameUnit OptionsObject Cod

Pagina 23

iContentsSection 1: Introduction to the MDrivePlus CANopen DSP-402 Implementation ...3Introduction ...

Pagina 24 - 16 MDrivePlus CANopen R020507

22 MDrivePlus CANopen R020507Entry DescriptionSub-Index Description Category Access PDO MappingValue Range Default Data Type01hEnable Capture Position

Pagina 25 - Section 3

23Part 2: DSP-402 ImplementationHold Current % By Device2205hMDrivePlus (All) MForce MicroDrive(Amps RMS)MForce PowerDrive (Amps RMS)10 MDrive Range 0

Pagina 26 - Unsigned 8

24 MDrivePlus CANopen R020507Entry DescriptionAccessR/KPDO MappingNoRangeN/ADefaultFactoryObject 5002h: ASCII Serial NumberThe following object is set

Pagina 27 - Entry Description

25Part 2: DSP-402 ImplementationSection 4Device ControlDevice ControlThe device control function block controls all the func-tions of the MDrivePlus C

Pagina 28 - Object 2010h: Analog Input

26 MDrivePlus CANopen R020507State Machine TransitionsTransition NumberFrom State To State Event/Action0StartNot Ready To Switch OnEvent: Reset.Action

Pagina 29 - Object 2033h: Capture Input

27Part 2: DSP-402 ImplementationPower DisabledPower EnabledFaultStartNot Ready to Switch OnFault Reaction ActiveFaultSwitch On DisabledReady To Switch

Pagina 30

28 MDrivePlus CANopen R020507Object 6040h — ControlwordThs controlword is a mandatory, unsigned 16 bit number containing bits for controlling the stat

Pagina 31 - Object 5001h: Configuration

29Part 2: DSP-402 ImplementationObject 6041h — StatuswordThe Statusword is a read-only object that indicates the current state of the drive, no bits a

Pagina 32

30 MDrivePlus CANopen R020507Bit 4: Voltage EnabledThe Disable Voltage request is active when the voltage_disabled bit is cleared to 0.Bit 5: Quick St

Pagina 33 - Section 4

31Part 2: DSP-402 ImplementationSection 5Modes of OperationObject 6060h — Modes of OperationThe performance of the MDrivePlus CANopen depends on the a

Pagina 34 - State Machine Transitions

iiObject 2006h: Input Filter Time (ms) ...19Object Description .

Pagina 35 - Statusword

32 MDrivePlus CANopen R020507Mode of Operation (6060h)Manuf. Specific ModesReservedReservedInterpolated Position ModeReservedProfile Position ModeProf

Pagina 36 - — Controlword

33Part 2: DSP-402 ImplementationLSBMSB31 16 15 10 9 8 7 6 5 4 3 2 1 0Profile PositionVelocityProfile Vel

Pagina 37 - Statusword (6041

34 MDrivePlus CANopen R020507Page Intentionally Left Blank

Pagina 38

35Part 2: DSP-402 ImplementationSection 6Profile Position ModeGeneral InformationA target_position is applied to the Trajectory Generator. It is genera

Pagina 39 - Section 5

36 MDrivePlus CANopen R020507Functional DescriptionThere are two different ways to apply target_positions to a drive, are supported by this device pro

Pagina 40 - Mode of Operation (6060

37Part 2: DSP-402 ImplementationV2V1T0T1T2T3VelocityTimetarget_position X1target_position X2Figure 6.3: Single Set-Point Mode (Move After a Move) 6040

Pagina 41 - 0 = Mode Not Supported

38 MDrivePlus CANopen R020507Statusword (6041h) of Profile Position Mode9 14 13 12 11 10 9 0See 1.4 Following Error Set-Point Acknowledge See 1.4 Targ

Pagina 42 - 34 MDrivePlus CANopen R020507

39Part 2: DSP-402 ImplementationObject 6082h — End VelocityThe end velocity defines the velocity which the drive must have on reaching the target posi

Pagina 43 - Section 6

40 MDrivePlus CANopen R020507Object 6086h — Motion Profile TypeThe Motion Profile Type is used to select the type of motion profile used to perform a

Pagina 44 - Functional Description

41Part 2: DSP-402 ImplementationSection 7Homing ModeGeneral InformationThis chapter describes the method by which a drive seeks the home position (als

Pagina 45 - ) of Profile Position Mode

iiiEntry Description ...32Data Descrip

Pagina 46

42 MDrivePlus CANopen R020507Statusword (6041h) of Homing Mode9 14 13 12 11 10 9 0See 1.4 Homing Error Homing Attained See 1.4 Target Reached See 1.4M

Pagina 47

43Part 2: DSP-402 ImplementationAxis Direction1Index PulseNegative Limit SwitchFigure 7.3: Homing on the Negative Limit and Index PulseHoming Method (

Pagina 48 - — Motion Profile Type

44 MDrivePlus CANopen R020507Method 2: Homing on the Positive Limit Switch and Index PulseUsing this method the initial direction of movement is right

Pagina 49 - Section 7

45Part 2: DSP-402 Implementation66Index PulseHome Switch55Figure 7.6: Homing on the Negative Home Switch and Index PulseMethods 7 to 14: Homing on the

Pagina 50 - Object Code

46 MDrivePlus CANopen R020507Home SwitchNegative Limit SwitchIndex Pulse141413121111111212131314Figure 7.8: Homing on the Home Switch and Index Pulse

Pagina 51 - Homing Method (6098h)

47Part 2: DSP-402 ImplementationMethods 33 and 34: Homing on an Index PulseUsing methods 33 or 34 the direction of homing is negative or positive resp

Pagina 52

48 MDrivePlus CANopen R020507Page Intentionally Left Blank

Pagina 53

49Part 2: DSP-402 ImplementationSection 8Position Control FunctionGeneral InformationIn this chapter, all parameters are described which are necessary

Pagina 54 - Methods 31 and 32: Reserved

50 MDrivePlus CANopen R020507Object 6065h — Following Error WindowThis object shall indicate the conFigure d range of tolerated position values symmet

Pagina 55 - Unsigned 32

51Part 2: DSP-402 ImplementationSection 9Profile Velocity ModeControlword (6040h) of Profile Velocity Mode15 9 8 7 6 3 0See 1.3 Ha

Pagina 56 - 48 MDrivePlus CANopen R020507

ivEntry Description ...50Object 6066h

Pagina 57 - Section 8

52 MDrivePlus CANopen R020507Object 60FFh — Target VelocityThe Target Velocity is the input to the trajectory generator and the value is given in micr

Pagina 58

53Part 2: DSP-402 ImplementationSection 10Optional Application FE (General I/O)Object 60FDh — Digital InputsThis object provides for digital inputs.Ob

Pagina 59 - Section 9

54 MDrivePlus CANopen R020507Object 60FEh — Digital OutputsThis object provides for digital outputs.Object DescriptionIndex60FEhNameDigital OutputsObj

Pagina 60 - — Maximum Slippage

WARRANTYTWENTY-FOUR (24) MONTH LIMITED WARRANTYIntelligent Motion Systems, Inc. (“IMS”), warrants only to the purchaser of the Product from IMS (the “

Pagina 61 - Section 10

© 2006 Intelligent Motion Systems, Inc. All Rights Reserved. REV020507IMS Product Disclaimer and most recent product information at www.i

Pagina 62 - 1 0

vList of FiguresFigure 1.1: Message Format ...

Pagina 63 - WARRANTY

viThis Page Intentionally Left Blank

Pagina 64 - Excellence in Motion

Excellence in MotionDSP-402 Application guideTMSection 1: Introduction to the MDrivePlus CANopen DSP-402 ImplementationSection 2: Manufactu

Comentarios a estos manuales